Home The quizzes about Chemical Examination of Urine (47 questions)

The quizzes about Chemical Examination of Urine (47 questions)

by MedQuizzes
The quizzes about Chemical Examination of Urine
0%

Leaving a reagent strip in the specimen for too long will:

Correct! Wrong!

Failure to mix a specimen prior to inserting the reagent strip will primarily affect the:

Correct! Wrong!

Testing a refrigerated specimen that has not warmed to room temperature will adversely affect:

Correct! Wrong!

The reagent strip reaction that requires the longest reaction time is the:

Correct! Wrong!

Quality control of reagent strips is performed:

Correct! Wrong!

Advertisement

All of the following are important to protect the integrity of reagent strips except:

Correct! Wrong!

The principle of the reagent strip test for pH is the:

Correct! Wrong!

A urine specimen with a pH of 9.0:

Correct! Wrong!

In the laboratory, a primary consideration associated with pH is:

Correct! Wrong!

The principle of the protein error of indicators reaction is that:

Correct! Wrong!

Advertisement

All of the following will cause false-positive protein reagent strip values except:

Correct! Wrong!

A patient with a 1 protein reading in the afternoon is asked to submit a first morning specimen. The second specimen also has a 1 protein. This patient is:

Correct! Wrong!

Testing for microalbuminuria is valuable for monitoring patients with:

Correct! Wrong!

All of the following are true for the Micral-Test for microalbumin except:

Correct! Wrong!

All of the following are true for the Immunodip test for microalbumin except:

Correct! Wrong!

Advertisement

The principle of the protein-low reagent pad on the Multistix Pro is the:

Correct! Wrong!

The principle of the creatinine reagent pad on microalbumin reagent strips is the:

Correct! Wrong!

The purpose of performing an albumin:creatinine ratio is to:

Correct! Wrong!

A patient with a normal blood glucose and a positive urine glucose should be further checked for:

Correct! Wrong!

The principle of the reagent strip tests for glucose is the:

Correct! Wrong!

Advertisement

All of the following may produce false-negative glucose reactions except:

Correct! Wrong!

A positive Clinitest and a negative reagent strip glucose are indicative of:

Correct! Wrong!

The primary reason for performing a Clinitest is to:

Correct! Wrong!

The three intermediate products of fat metabolism include all of the following except:

Correct! Wrong!

The most significant reagent strip test that is associated with a positive ketone result is:

Correct! Wrong!

Advertisement

The primary reagent in the reagent strip test for ketones is:

Correct! Wrong!

Ketonuria may be caused by all of the following except:

Correct! Wrong!

Urinalysis on a patient with severe back and abdominal pain is frequently performed to check for:

Correct! Wrong!

The principle of the reagent strip test for blood is based on the:

Correct! Wrong!

A speckled pattern on the blood pad of the reagent strip indicates:

Correct! Wrong!

Advertisement

The principle of the reagent strip test for bilirubin is the:

Correct! Wrong!

An elevated urine bilirubin with a normal urobilinogen is indicative of:

Correct! Wrong!

The primary cause of a false-negative bilirubin reaction is:

Correct! Wrong!

The purpose of the special mat supplied with the Ictotest tablets is that:

Correct! Wrong!

The reagent in the Multistix reaction for urobilinogen is:

Correct! Wrong!

Advertisement

The primary problem with urobilinogen tests using Ehrlich reagent is:

Correct! Wrong!

In the Watson-Schwartz differentiation test, the substance(s) not extracted into butanol is/are:

Correct! Wrong!

The Hoesch test is used to monitor or screen patients for the presence of:

Correct! Wrong!

The reagent strip test for nitrite used the:

Please select 2 correct answers

Correct! Wrong!

All of the following can cause a negative nitrite reading except:

Correct! Wrong!

Advertisement

A positive nitrite test and a negative leukocyte esterase test is an indication of a:

Correct! Wrong!

All of the following can be detected by the leukocyte esterase reaction except:

Correct! Wrong!

Screening tests for urinary infection combine the leukocyte esterase test with the test for:

Correct! Wrong!

The principle of the leukocyte esterase reagent strip test uses a:

Correct! Wrong!

The principle of the reagent strip test for specific gravity uses the dissociation constant of a/an:

Correct! Wrong!

Advertisement

A specific gravity of 1.030 would produce the reagent strip color:

Correct! Wrong!

Reagent strip–specific gravity readings are affected by:

Correct! Wrong!

The quizzes about Chemical Examination of Urine (47 questions)
You need to try more!
You are pretty good!
You are very good!

Share your Results: